Biocare Products
Biocare Medical Decloaking Chamber

Biocare Medical Decloaking Chambers™

Biocare Medical’s Decloaking Chambers are the most validated and well-published tools for heat-induced epitope-retrieval (HIER) methods. The proper use of heat and pressure in conjunction with the appropriate buffer solutions is of the utmost importance for consistent immunohistochemistry (IHC) staining. Decloaking Chambers are designed to optimize and standardize antibody staining procedures and have been engineered to pass strict laboratory safety requirements. Temperature, pressure and pH can be monitored and recorded with the Decloaking Chambers to produce consistent staining, which will reduce repeat testing and false negatives.

Furthermore, all Decloaker HIER solutions incorporate Assure™ color-coded pH indicator technology, indicating by visual inspection that the solution is at the correct dilution and pH. Biocare Medical Decloaking Chamber

Decloaking Chamber™ Plus

The new and improved Decloaking Chamber™ Plus has been redesigned with a programmable walk-away capability, a cooling fan for more rapid antigen retrieval and an optional stainless steel rack holder for easy removal of plastic slide containers. Furthermore, a USB port enables the laboratory to utilize a flash drive to track and save run data for quality control purposes. The pressure gauge has a new feature in which the needle remains at the highest pressure reading during the run, validating that antigen retrieval has occurred properly. When the procedure is completely finished, an audible beep alerts the user.



Decloaking Chamber™ Plus (for use within the United States):

Cat. No. Description
DC2008US-RH With Rack Holder; 110-120V, 800W, 60Hz
DC2008US Without Rack Holder; 110-120V, 800W, 60Hz
Size: 12"W x 11"H, 8.2 lbs.

Decloaking Chamber™ Plus (for international use):

Cat. No. Description
DC2008INTL-RH With Rack Holder; 220-240V, 900W, 50Hz    
DC2008INTL Without Rack Holder; 220-240V, 900W, 50Hz
Size: 12"W x 11"H, 8.2 lbs.


Biocare Medical Decloaking Chamber (DC2002)Biocare Medical Decloaking Chamber

The Decloaking Chamber is a pressure cooker for heat induced epitope retrieval with variable temperature, fully integrated digital control. It is programmable for time and temperature, includes an automatic audible warning system. This model also has the pressure gauge, “HOT” sticker and 3-prong laboratory safe grounded plug. Up and down arrow keys allow user to select temperature from 37° to 125° C. Useful for HIER as well as Special Stain procedures. Available for 220V or CE approved. U.S. patent number 6,580,056, June 17, 2003.

 

Cat. No. Description
DC2002-220 Pressure Cooker for HIER, 220 V
DC2002-CE Pressure Cooker for HIER, CE approved
Size: 12"W x 11"H, 8.2 lbs.

Biocare Medical Microtiter Plate Platform

Biocare Medical Microtiter Plate PlatformThe Biocare Microtiter Plate Platform, is for free floating sections. The Platform holds the microtiter plates away from the source of heat used in HIER, allowing for more even, standardized results. This Platform was developed to support microtiter plates during antigen retrieval within an HIER instrument. Standard microtiter plates holding free floating sections are filled with a retrieval solution, placed on the Microtiter Plate Platform, which is then be lowered into a pressure system for heat induced antigen retrieval (ie, the Decloaking Chamber from Biocare). This is especially critical when using thick sections of delicate tissue such as brain tissues. The Microtiter Plate Platform also stabilizes the specimens and enables ease of use. It has been rigorously tested for heat stability and is ISO compliant.

Name Cat. No. Datasheet
Microtiter Plate Platform MPP001 Datasheet

 

 

 


Decloaking Chamber Accessories

Name Cat. No. Description
Rack Holder RMDC085  1 each 
Decloaking Chamber gasket DC2000-GKT-1 1 each
Kling-On Slides SFH1103A, B 1, 10 gross
Steam Monitor Strips 613C, D, H 100, 250, 25-pack
Quality pH Strips, pH 4-7 pH615 100-pack
Quality pH Strips, pH 7.5-10.5 pH616 100-pack
Tissue Tek Slide Holders and Containers TTSET-4PK 4-pack
Coplin Jar CJ-3PK 3-pack


Decloaking Solutions

Name Cat. No. Volume Description
Bull’s Eye Decloaker (20X) BULL1000L2JX, MX 250, 500 ml Universal Solution, pH 6.0
Bull’s Eye Decloaker (1X) BULL1000MM, G1 1000 ml, 1 gallon Ready-to-use, pH 6.0
Antigen Decloaker CB910M 500 ml Citrate Buffer,
pH 6.0
Antigen Decloaker (1X) CB915MM 1000 ml Citrate Buffer,
pH 6.0
Nuclear Decloaker, (10X) CB911M 500 ml Tris Buffer, pH 9.5
Nuclear Decloaker, (1X) CB916MM 1000 ml Tris Buffer, pH 9.5
EDTA Decloaker (5X) CB917L, M 100, 5x100 ml EDTA buffer, pH 8.5-8.7, concentrate


Two-Step Deparaffinization and Heat Induced Epitope Retrieval Solutions

Name Cat. No. Volume Description
Universal Decloaker UD1000L, M 100, 500 ml HIER Solution
BORG Decloaker BDS1000S-250, MM, G1 250, 1000 ml, 1 gallon HIER Solution,
Ready-to-use
BORG Decloaker BDS1000G1 1 gallon includes 25 Steam Monitor Strips
Reveal (10X) RV1000M 500 ml HIER Solution
Reveal (1X) Rv1000G1, MMRTU 1 gallon, 1000 ml HIER Solution, Ready-to-use
Reveal (10X) RVS1000M-RVS 500 ml + 25 Steam Strips Includes 25 Steam Monitor Strips
HOT RINSE HTR1001L, M 100m 500 ml Post-rinse for Reveal, BORG or Universal Decloaker


Biocare Medical Decloaking Chamber Steam StripSteam Monitor Strips and pH Strips for Quality Control
The steam monitor strips are heat and pressure sensitive which allows the user to ensure that the chamber has reached full temperature and pressure as evidenced by the charcoal black color. The strips can be placed in your laboratory notebook as a permanent record for that run. QC pH Strips provide a permanent visual QC record of HIER procedures. QC pH Strips record pH at high temperatures.

Quality Control Cat. No. Description
Steam Monitor Strips 613C, D, H 25, 100, 250-pack
QC pH Strips pH 4-7 pH615 100-pack
QC pH Strips pH 7.5-10.5 pH616 100-pack